A customer using our company’s EXT-2, but we have been informed that the wire will break in about two years, so we visited to check the situation.
However, the customer was also aware that there was no problem with the cable and that there was a problem with the wiring environment.

Investigate cause

We obtained a sample of the cable that was actually disconnected and conducted an analysis survey.

We observed wear on the sheath of the sample cables,after that we reported the analysis status to the customer.

It was confirmed that the cause of cable sheath scraping was contact between the robot base (metal board) and the cable. We confirmed the problem with the outer diameter and wiring of the cables.

Proposal from Taiyo Cable Group

In addition to reviewing the wiring, we proposed a method that does not put stress on the cable by using two 10p (10 pairs) instead of one 40-core cable, and proceeded to prototype evaluation.

Proposed review of wiring. We suggested changing the cable type. (40-core/1-cable changed to 10-pair/2-cables. ) The burden on the cable was reduced and smooth wiring was possible.

Summary

We received a good evaluation from the customer that the level of the sample analysis research was high, and finally adopted the proposed product.

If you have any problems with robot cables, please contact Taiyo Cable Group!

BACK TO CASE STUDY

For cables, contact us

Contact us by Phone

Shanghai Head Office021-62889868

Shanghai sales office 021-62888068 Beijing sales office 010-84783633
Suzhou sales office 0512-62891229 Suzhou factory 0512-62891228
Dongguan sales office 0769-39018819 Dongguan factory 0769-39018818

Monday to Friday 8:30 AM - 5:30 PM