The selection of qualified wire and cable products is related to the safety of people's production and life. For ordinary consumers, in addition to knowing how to select qualified wire and cable products, it is necessary to understand the routine monitoring knowledge of wire and cable. In the quality inspection of wire and cable, there are mainly the following important indicators.
Wire and Cable
Insulation resistance test:
Insulation resistance reflects an important indicator of the insulation properties of wire and cable products. It is closely related to the electrical strength of the product, the dielectric loss, and the gradual deterioration of the insulation under working conditions. For communication cables, too low insulation resistance between lines will increase loop attenuation, crosstalk between circuits, and long-distance power supply leakage on conductive cores. Therefore, insulation resistance should be higher than the specified value.
Determining the insulation resistance can find defects in the process, such as insulation drying or sheath damage and moisture; insulation is contaminated and conductive impurities are mixed; cracking of the insulation layer caused by various reasons. In the operation of wires and cables, it is often necessary to detect the insulation resistance and leakage current as the main basis for whether or not to continue safe operation.
At present, the measurement of insulation resistance of wire and cable, in addition to the use of ohmmeter (shaking table), is commonly used galvanometer comparison method high resistance meter method (voltage - current method).
Measurement of capacitance and loss factor:
When the cable is connected to the AC voltage, current flows. When the amplitude and frequency of the voltage are constant, the magnitude of the capacitor current is proportional to the capacitance of the cable (Cx). For ultra-high voltage cables, the current of such capacitors may reach a value comparable to the rated current, which is an important factor limiting cable capacity and transmission distance. Therefore, the capacitance of the cable is also one of the main electrical performance parameters of the cable.

For cables, contact us
Contact us by Phone
Shanghai Head Office021-62889868
| Shanghai sales office | 021-62888068 | Beijing sales office | 010-84783633 |
| Suzhou sales office | 0512-62891229 | Suzhou factory | 0512-62891228 |
| Dongguan sales office | 0769-39018819 | Dongguan factory | 0769-39018818 |
Monday to Friday 8:30 AM - 5:30 PM